Installation volume calculator

Work out the installation volume (IV) for a tightness test and purge, to IGEM/UP/1B.

How it works

  1. Enter each pipe run by material and size, and the meter in the test section. Mantle totals the pipework volume, adds the meter internal volume, and includes fittings as +10% on the pipework (the per-metre figures already include it).
  2. From the total IV it shows the permissible pressure drop, scaled to the installation volume rather than the meter size, and the purge volume (1.5 × IV).
  3. The result feeds the same figures a tightness test record needs, so the numbers carry straight across.

Common questions

Which edition?

IGEM/UP/1B Edition 4, published March 2026 and mandatory from 1 October 2026. Earlier work should still follow the edition in force at the time.

Why does the permissible drop scale to IV?

Because the allowable drop depends on the installation volume in the test section, not simply on the meter. Mantle computes it from the IV you enter.

Want the certificates, reminders and the full Tool Box?

Mantle is free for UK Gas Safe engineers: CP12 gas safety certificates, service records, customer reminders and seven field calculators in your pocket. Get started.

Other free calculators

This calculator is a design and field aid, not a substitute for the manufacturer’s instructions or Gas Safe guidance. Where they disagree, the maker’s data and Gas Safe win. Always work to the current standard.