Ventilation calculator

Work out the permanent ventilation free area a gas appliance needs, to BS 5440-2:2009.

How it works

  1. Choose the appliance type and enter its input rating. Open-flued appliances and flueless appliances are calculated differently, and the multi-appliance rule adds the next-largest requirement on top of the largest.
  2. Room-sealed appliances normally take their combustion air from outside and need no room vent, but the maker’s instructions always come first.
  3. Mantle shows the required free area in cm². Air vents are measured for free area, not the hole size, and an existing vent may need checking for blockage.

Common questions

Where does the rule come from?

BS 5440-2:2009, covering the air supply for open-flued and flueless appliances and appliance compartments.

What about a room with two appliances?

The multi-appliance rule applies: the largest individual requirement plus half of the next largest. Mantle applies it when you enter more than one appliance.

Want the certificates, reminders and the full Tool Box?

Mantle is free for UK Gas Safe engineers: CP12 gas safety certificates, service records, customer reminders and seven field calculators in your pocket. Get started.

Other free calculators

This calculator is a design and field aid, not a substitute for the manufacturer’s instructions or Gas Safe guidance. Where they disagree, the maker’s data and Gas Safe win. Always work to the current standard.